IDEXX StatSpin VT Veterinary Centrifuge with Rotor and Power Supply
$ 499.09
- Description
- Size Guide
Description
Good, Working StatSpin VT Veterinary Centrifuge with RM02 Rotor and Power Supply.VT Specifications -
Setting
RPM/RCF
Time
Rotor
Quick Spin
15,800/12,000
30 seconds
RT12, RM02
Normal
15,800/12,000
90 seconds
RT12, RM02
Hard Spin
15,800/12,000
150 seconds
RT12, RM02
Urine Sediment
9,800/3,900
45 seconds
RT12
Microhematocrit 15,800/13,700
120 seconds
RH12
Description of rotors -
RT12 Tube Rotor - This 2-place rotor is designed to accommodate a variety of StatSpin
tubes for blood and urine separation, as well as standard 1.5 mL and 2.0 mL
microcentrifuge tubes with a maximum diameter of 10.9 mm. All tubes used in the rotor
must be "top-supported" (supported by a flange near the mouth of the tube). Do not use
glass pediatric-style blood tubes even though they may appear to fit. The following tubes
are approved for use in this rotor:
Prepared Microtubes: StatSpin TP1H (green top); TP1U (red top); TP5G (gel tube);
CH03 (capillary collector).
StatSamplers®: StatSpin SS2H, SS2U, SS2X, SS1E, SS2E.
Precalibrated Urine Tube: StatSpin TU15.
LipoClear Reagent Tubes: StatSpin LC40; LC15; LC10.
Capiject® blood collection tubes (Terumo®).
Standard 1.5 - 2.0 mL microcentrifuge tubes (e.g. Eppendorf®)
BD Microtainer® with FloTop® Collector – must use SV12 Microtainer® Adaptor
BD Microtainer® with Microgard closure
RM02 Tube Rotor - Designed specifically for B-D Microtainer® brand tubes, this 2-place
rotor also accepts standard 0.5 mL microcentrifuge tubes. Maximum tube diameter is 8.3
mm. The following tubes are approved for use in this rotor:
BD Microtainer® FloTop® Collector - all formats except those with Microgard
closures.
0.5 mL microcentrifuge tubes (7.5 mm O.D. x 35 mm L.)
Important: The RT12 and RM02 tube rotors must be balanced before operation. If only
one sample is being processed, a second sample can serve as the balance tube or use a
similar tube filled with water as balance.
RH12 Microhematocrit Rotor - This 12-place covered rotor is used to centrifuge
StatSpin microcapillary tubes for microhematocrit testing. Maximum tube size is 1.7 mm
O.D. x 42 mm L. It is recommended that rubber cushions provided with the rotor be
replaced twice a year or whenever a tube breaks in the rotor. Order StatSpin 01-2002-04
for a replacement set of 12 cushions. The following tubes are approved for use in the
rotor:
StatSpin glass capillary tubes: HT9H; HT9U.
StatSpin SafeCrit® plastic capillary tubes: HP8H; HP8U.